Hawke's Bay 120 Pre-wired System - MNHAWKE'S BAY 120 PW
|
Nominal Battery Voltage
|
48V
|
Maximum Output Current
|
120 Amps
|
PV Open Circuit Voltage VOC
|
600VDC
|
Power Conversion Efficiency
|
98% (Typical system)
|
Arc Fault and NEC 2020 Ground Fault Protection
|
Optional plugin modules - user installed
|
Charging Regulation
|
Bulk, Absorb, Float as well as Equalization
|
Battery Voltage Regulation Set Points
|
40V to 65V
|
Equalization Charging
|
Adjustable voltage and duration
|
Battery Over Voltage
|
Fully protected. The optional Barcelona Breaker Box (MNBCLNA BB) automatically trips PV input breaker if battery exceeds 68VDC
|
Battery Short Circuit
|
Fully protected
|
Battery Temp Compensation
|
Automatic when BTS is installed. Adjustable mV per degree C per 2V cell
|
Programmable Auxiliary
|
2 auxiliary outputs
|
Graphic Display
|
MNGP2 - 64 x 122
|
Stacking cables for system networking
|
Standard CAT5 - Canbus
|
Communications
|
Canbus
|
Remote Display
|
MNGP2 can be relocated and a second display can be added
|
Firmware updates
|
Phone Application software for firmware updates
|
Terminal Rating
|
75C
|
Data Logging
|
380 days of daily history
|
Positive Ground Applications
|
Requires 2 pole input and output breakers
|
Operating Temperature
|
Minimum of -40C to 50C (controller will auto derate as temperature rises above 25C)
|
Environmental Rating
|
Indoor type 1
|
Warranty
|
7 Years
|
Weight & Dimensions
|
xx lbs. 32.30” x 9.79” x x”
|
Shipping Dimensions
|
40 x 16.5 x 12 (inches)
|
Certifications
|
Listed by ETL for US & Canada
|